Effects of simulated gastric acid ageing on Martens hardness of denture base resins fabricated using different techniques.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Abdulaziz Alhotan; Ahmed Altarazi; Shaymaa Mudhaffer; Hanan Al-Johani; Nick Silikas

Publication details

Dental materials : official publication of the Academy of Dental Materials · 2026 · Vol. 42 · No. 12 · Pages/article no. 2316-2323

Publication date (as recorded): 2026-11-30

PMID: 42386449

Abstract (original)

Gastro-oesophageal reflux disease exposes denture base resins to acidic conditions that may compromise their mechanical properties. This study assessed the effect of simulated gastric acid ageing on the Martens parameters of heat-polymerised, CAD/CAM milled, and 3D-printed polymethyl methacrylate (PMMA). OBJECTIVES OBJECTIVE

Three denture base resins were investigated: heat-polymerised (Lucitone 199), CAD/CAM milled (G-CAM), and 3D-printed (Denturetec). Specimens (n = 5 per group) were aged in artificial saliva (pH 5.5) or simulated gastric acid (pH 1.2) at 37°C for 24 and 96 h, corresponding to approximately 2.5 and 10 years of clinical exposure. Martens indentation testing was performed, and the following parameters were measured; Martens hardness (H), indentation depth (I), indentation modulus (E), and creep indentation (C). Data were analysed using two-way ANOVA and Tukey post hoc tests (α = 0.05). METHODS METHODS M D IT IT

Resin type significantly affected all Martens parameters (p < 0.001), with milled resin exhibiting the highest H and E values and 3D-printed resin showing the highest I values. Ageing solvent significantly impacted H, I, and E (p ≤ 0.049). Gastric acid exposure caused significant deterioration in Martens parameters, particularly at 96 h. Heat-polymerised and milled PMMA exhibited significant differences between solvents at specific time points, whereas 3D-printed resins remained largely unaffected by the ageing solvent. RESULTS RESULTS M IT D M D IT

These findings suggest that material selection based on fabrication technique may influence denture longevity in patients with chronic acid exposure, such as those with gastro-oesophageal reflux disease or eating disorders. The immersion-to-clinical time equivalence represents an approximation based on previously published accelerated ageing models and should be interpreted as a standardised testing protocol rather than an exact clinical simulation. SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42386449/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Multicenter RCT 6-Year Survival of Zirconia-Reinforced Lithium Silicate Endocrowns: 90° Shoulder Versus Butt-Joint Margins.

Следующая публикация

A high-filler-content 3D-printable composite enabled by a novel silanization process bridging the performance gap with milled materials for definitive dental prostheses.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее