Thermoformed versus directly 3D-printed clear aligner materials: A comparative in vitro study of thermomechanical behaviour, chemical extractables, and shape-memory performance.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Bismina Noushad; Achint Juneja; Monis Raza; Prashant Kumar Shahi; Ridhi Kothari; Prachi Mehra

Publication details

International orthodontics · 2026 · Vol. 24 · No. 4 · Pages/article no. 101204

Publication date (as recorded): 2026-11-30

PMID: 42398221

Abstract (original)

To compare thermoformed polyurethane aligners (Zendura®) and directly 3D-printed shape-memory aligners (TC-85™) in terms of thermomechanical behaviour, chemical extractables, and shape-recovery performance. OBJECTIVE OBJECTIVE

In this in vitro comparative study, standardized specimens (n=22/group) were evaluated using differential scanning calorimetry (Tg, ΔCp), gas chromatography-mass spectrometry (ISO 4049 extractables), and shape-recovery testing at multiple temperatures; time-dependent stress relaxation under constant strain (2% tensile strain, 180min, 37°C) was additionally evaluated as a viscoelastic measure of orthodontic force decay. Measurements were recorded at baseline and after 7 days of artificial saliva ageing. Statistical analysis was performed using parametric and non-parametric tests (P≤0.05). MATERIAL AND METHODS METHODS

Both materials showed increased extractables after ageing (P<0.05). Zendura exhibited significantly higher cumulative extractables than TC-85™ (P<0.001). ΔCp remained stable in both groups, with higher values in TC-85™ (P<0.001). Tg remained stable for Zendura but decreased slightly for TC-85™ (P=0.043), with TC-85™ demonstrating lower Tg overall (P<0.001). Shape recovery decreased after ageing in both materials but remained significantly higher in TC-85™ (P<0.001). Under constant strain, TC-85™ underwent significantly less stress relaxation than Zendura® (27.2±0.5% vs. 41.3±0.4%; P<0.001) and retained a higher residual force at 180min (72.8% vs. 58.7%), indicating more sustained force delivery in vitro. RESULTS RESULTS

Directly 3D-printed TC-85™ aligners demonstrated lower extractables, favourable thermal properties, greater resistance to stress relaxation, and superior shape-recovery behaviour compared with thermoformed Zendura® under short-term ageing conditions. These differences reflect material behaviour under standardized bench conditions and should not be interpreted as direct evidence of superior clinical force delivery or biocompatibility. CONCLUSION CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42398221/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

A high-filler-content 3D-printable composite enabled by a novel silanization process bridging the performance gap with milled materials for definitive dental prostheses.

Следующая публикация

Effect of a stackable scanning guide, intraoral scanner type, and operator on the accuracy of maxillary full-arch implant scans: An in vitro study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее