Original PubMed abstract — English. No translation or clinical interpretation.
Authors
Manuel Aeschbacher; Steven Sonderegger; Seyed Ali Mosaddad; Stefano Pieralli; Pedro Molinero-Mourelle; Cecilia Santos Galvao; Burak Yilmaz; Gülce Çakmak
Publication details
Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106964
Publication date (as recorded): 2026-11-30
PMID: 42556701
Abstract (original)
This study evaluated the influence of polymerization units and support bar design on the trueness and fit of complete-arch implant-supported frameworks fabricated using digital light processing (DLP) additive manufacturing (AM) and compared their performance with a subtractively manufactured (SM) control. OBJECTIVE OBJECTIVE
A maxillary complete-arch framework was designed and fabricated using six conditions combining two polymerization units (xenon-flash light under nitrogen [XFN] and light-emitting diode [LED]) and three support bar designs (no-bar, Y-shaped bar, horizontal-bar), along with an SM reference framework (n = 10). Fabrication trueness was evaluated by analyzing surface deviations across predefined regions (overall framework, occlusal, non-occlusal, and abutment surfaces) and by measuring linear abutment-level and interimplant distance deviations using metrology software. Marginal gap, used as a fit indicator, was assessed using a digital triple-scan protocol. Test and control group differences were analyzed by one-way ANOVA (Dunnett), and those across AM groups by two-way ANOVA (Bonferroni; α = 0.05). METHODS METHODS
Support bar design significantly influenced trueness (p < 0.001); no-bar frameworks generally demonstrated the highest trueness. The polymerization unit showed limited main effects on trueness, although a significant effect was observed for overall RMS (p = 0.024). For linear deviation, interimplant distance, and marginal gap, outcome-dependent polymerization unit × support bar design interactions were identified (p < 0.05). XFN polymerization yielded lower linear deviations at selected implant sites, whereas LED polymerization was associated with lower interimplant distance deviations and reduced marginal gaps at specific locations. RESULTS RESULTS
Support bar design was the primary factor influencing dimensional trueness, with no-bar configurations generally demonstrating higher trueness. Polymerization unit effects were outcome- and geometry-dependent, with no consistent overall difference between XFN and LED. CONCLUSIONS CONCLUSIONS
Under the tested laboratory conditions, omitting support bars was associated with lower surface deviations in DLP-printed frameworks. However, the site- and geometry-dependent marginal gap findings do not establish a clinically preferable support or polymerization protocol and require mechanical and clinical validation. CLINICAL SIGNIFICANCE CONCLUSIONS
Source: https://pubmed.ncbi.nlm.nih.gov/42556701/