Dimensional and angular agreement of LCD printed zirconia nanohybrid orthodontic brackets with CAD targets in a single build in vitro study.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Anthony Allison; Rafael Delgado-Ruiz; Duane Shank; Richard Faber

Publication details

International orthodontics · 2026 · Vol. 24 · No. 4S · Pages/article no. 101254

Publication date (as recorded): 2026-11-30

PMID: 42874307

Abstract (original)

To quantify the within-build agreement of linear dimensions and slot-wall angulation of custom orthodontic brackets fabricated by LCD-masked vat photopolymerization with their nominal computer-aided design (CAD) targets. INTRODUCTION BACKGROUND

Fifty brackets were fabricated in one build by one operator using a zirconia nanohybrid photopolymer resin (Rodin Sculpture 2.0). Two examiners measured four outcomes using ImageJ and Geomagic Control X, with three repetitions per examiner and program. Only the 12-reading mean for each specimen and outcome was retained. Means, standard deviations (SDs), confidence intervals (CIs), and conformity with investigator-defined margins (±0.05mm and ±0.35°) were summarized. These margins were not validated clinical thresholds. The brackets were technical replicates of one build; measurement reliability and between-build reproducibility could not be estimated. METHODS METHODS

The 50 consolidated specimen-level values yielded means (SDs) of 0.557 (0.015) mm for slot height, 0.711 (0.017) mm for slot depth, 0.999 (0.006) mm for base height, and 7.032° (0.174°) for slot-wall angulation. The corresponding 95% CIs were 0.552-0.561mm, 0.706-0.716mm, 0.997-1.000mm, and 6.982°-7.081°. Specimen-level conformity with the investigator-defined limits was 94%, 94%, 100%, and 96%, respectively. RESULTS RESULTS

In this single build completed by one operator, mean linear dimensions and slot-wall angulation were close to the CAD targets. The results describe geometric agreement of averaged measurements within that build; they do not establish measurement reliability, workflow reproducibility, or clinical material suitability. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42874307/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Digital workflows for immediate implant placement and soft-tissue management in the esthetic zone: A scoping review.

Следующая публикация

Alveolar Bone Regeneration Using 3D-Printed, Patient-Specific, Resorbable PCL Scaffold: Prospective Cohort Study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее