A high-filler-content 3D-printable composite enabled by a novel silanization process bridging the performance gap with milled materials for definitive dental prostheses.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Christelle Sanchez; Renaud Noharet; Raphael Herman; Alain Vanheusden; Amélie Mainjot

Publication details

Dental materials : official publication of the Academy of Dental Materials · 2026 · Vol. 42 · No. 12 · Pages/article no. 2257-2264

Publication date (as recorded): 2026-11-30

PMID: 42350179

Abstract (original)

This study evaluated the mechanical and fatigue properties of an experimental high-filler-content 3D-printable dental composite incorporating a novel silanization process (Magnus), designed to increase filler content without increasing viscosity and to enhance the filler-resin interface, in comparison with commercial printed and milled composite materials. OBJECTIVE OBJECTIVE

Magnus specimens were fabricated by MSLA (Phrozen). They were compared with 3D-printed OnX Tough2 (Sprintray) and milled Grandio CAD-CAM composite blocks (Voco) produced following manufacturer's recommendations. Bar specimens underwent three-point flexural testing (n = 30/material) and cyclic flexural fatigue at 150 MPa (1 Hz; n = 20/material). All tests were conducted in a 36°C water bath. Vickers microhardness, filler content, resin viscosity and degree of conversion were assessed. METHODS METHODS

Magnus exhibited the highest filler content reported (∼70 wt%, 53 vol%), approximately twice that of OnX Tough2 (∼35 wt%, ∼22 vol%), while maintaining lower shear viscosity. At 150 MPa, Magnus demonstrated flexural fatigue resistance 4.1-fold higher than Grandio blocs and approximately 2,100-fold higher than OnX Tough2. Flexural strength was equivalent to Grandio blocs (209.7 vs 219.3 MPa), with similar Weibull modulus. Flexural modulus was 3.2-fold higher than OnX Tough2 (7.4 vs 2.3 GPa). Fracture energy and microhardness were markedly higher than OnX Tough2. Degree of conversion exceeded 95%. RESULTS RESULTS

Under clinically relevant wet testing conditions, this very high-filler-content 3D-printable composite maintained low viscosity while achieving markedly superior fatigue resistance compared with the tested printed and milled materials and flexural strength comparable to the milled reference, thereby bridging the mechanical performance gap between printed and milled restorative materials. SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42350179/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Effects of simulated gastric acid ageing on Martens hardness of denture base resins fabricated using different techniques.

Следующая публикация

Thermoformed versus directly 3D-printed clear aligner materials: A comparative in vitro study of thermomechanical behaviour, chemical extractables, and shape-memory performance.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее