Accuracy of full-arch digital implant impression and bite registration: effect of different reference object strategies and intraoral scanners.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Vygandas Rutkūnas; Andrius Kubilius; Mykolas Akulauskas; Judit Borbély; Barbara Kispélyi; Viktória Vitai; Dominykas Stasiūnas

Publication details

Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106802

Publication date (as recorded): 2026-11-30

PMID: 42285209

Abstract (original)

This in vitro study evaluated the accuracy of digital impressions for full-arch implantsupported restorations by assessing scan body (SB) positional accuracy and inter-arch registration under different intraoral scanners (IOS) and scan protocol conditions. OBJECTIVES OBJECTIVE

Two IOSs (Medit i700 and Trios 5) were evaluated across multiple protocols. In Part A, SB trueness and precision were investigated using three inter-implant distances (1-2, 1-3, 1-4) and angulations across five groups (n = 10 each), with and without reference objects (ROs) on an edentulous maxillary model. In Part B, inter-arch distance accuracy was evaluated with the help of four sphere pairs used in the same upper edentulous arch with implants and a dentated mandibular model in an articulator using six scanning protocols, including one- and two-step bite registration. Trueness and precision were analyzed using linear mixed-effects models for each data type. METHODS METHODS

In Part A, Medit i700 with ROs (A-M700-RO) showed the highest trueness and precision in both linear and angular SB measurements. RO use significantly improved performance, particularly for Trios 5. Angular deviation was lowest in A-M700-RO, especially in distal segments (mean difference -0.24°, p < 0.05). In Part B, Trios 5 with a two-step RO bite registration (B-T5-RO-1) had the highest inter-arch accuracy, especially in molar regions. Accuracy in this group was significantly higher than all other groups (p < 0.01). RESULTS RESULTS

Digital impression accuracy is influenced by both the scanner type and scanning protocol. Additional reference objects improved the accuracy of distance measurements but did not significantly affect measurements of angulation. Medit i700 outperforms in SB accuracy, while Trios 5 excels in inter-arch registration when combined with ROs and a two-step protocol. CONCLUSIONS CONCLUSIONS

Additional reference objects may improve the digital implant impressions' distance accuracy, although they do not significantly affect angulation outcomes. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42285209/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Fatigue lifetime and microbial inhibition at the implant-abutment interface of 5Y-PSZ zirconia abutments coated with experimental glass.

Следующая публикация

Digital cross-section mapping: automated 3D quantification of peri-sulcular structures adjacent to epi- and subgingival finish lines in digital dentistry.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее