Digital cross-section mapping: automated 3D quantification of peri-sulcular structures adjacent to epi- and subgingival finish lines in digital dentistry.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Majed Kutaini; Sven Reich

Publication details

Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106809

Publication date (as recorded): 2026-11-30

PMID: 42242616

Abstract (original)

To present a digital workflow that enables circumferential identification of anatomical landmarks and automated measurement of peri‑sulcular structures adjacent to epi‑ or subgingival finish lines. OBJECTIVES OBJECTIVE

Five predominantly subgingivally prepared teeth were included. For each tooth, three STL files were obtained: an intraoral scan, a digitized conventional master-cast scan, and the same intraoral scan including the surrounding gingiva. Margin datasets were trimmed, then aligned with the gingival dataset using MarginSlicer, a custom Python program, with semi-automated best-fit registration. The merged dataset was sectioned into 360 transverse slices. Predefined landmarks and distances, including the sulcus floor, papilla vertex, sulcus width, sulcus depth, and preparation depth, were automatically identified and exported in 5° increments. METHODS METHODS

Of 365 exported cross sections, 349 (95.6%) yielded calculable margin deviations. Landmarks required for peri‑sulcular measurements were identified in 238 sections for sulcus width (65.2%), 235 for sulcus depth (64.4%), and 257 for preparation depth (70.4%). Per-tooth mean values (mm) ranged from 0.64 ± 0.16 to 0.75 ± 0.21 (sulcus width), 0.77 ± 0.30 to 1.37 ± 0.71 (sulcus depth), and 0.40 ± 0.24 to 0.93 ± 0.62 (preparation depth). Positive margin deviations predominated in all teeth, accounting for 75.8% to 92.5% of measurements. RESULTS RESULTS

The proposed workflow enables automated two-dimensional measurements from three-dimensional datasets and permits circumferential geometric analysis of prepared teeth relative to surrounding gingival tissue. CONCLUSIONS CONCLUSIONS

The workflow provides automated circumferential quantification of peri‑sulcular structures and finish-line capture in digital scans. These standardized measurements can be integrated into digital analysis pipelines to enhance CAD workflow accuracy, improve evaluation of intraoral scanner performance, and increase the reliability of digitally fabricated restorations. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42242616/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Accuracy of full-arch digital implant impression and bite registration: effect of different reference object strategies and intraoral scanners.

Следующая публикация

Comparative analysis of monomer elution, polymerization efficiency, mechanical properties and biocompatibility of 3D-printed provisional and permanent dental resins.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее