Effect of printing temperature on the viscosity, photopolymerization, and mechanical properties of a highly filled 3D-printing dental resin composite.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Ulysses de Toledo Monteiro; Américo Bortolazzo Correr; Mateus G Rocha

Publication details

Journal of the mechanical behavior of biomedical materials · 2026 · Vol. 184 · Pages/article no. 107640

Publication date (as recorded): 2026-11-30

PMID: 42790194

Abstract (original)

This study aimed to evaluate the effect of three printing temperatures on the viscosity; cure depth (Cd) and working-curve parameters (Dp, Ec); degree of conversion (DC) and polymerization kinetics; and post-cured flexural strength (FS), flexural modulus (FM), and the Weibull reliability of flexural strength of a highly filled dental resin composite. OBJECTIVE OBJECTIVE

Viscosity (n = 3) was characterized between 20 and 55 °C using a rheometer under steady-shear and shear-rate sweep protocols. Three 3D printing temperatures (25, 37, and 50 °C) were compared regarding photopolymerization and mechanical properties. Cure depth (Cd) (n = 10) was measured by polymerizing confined resin composite in a ring mold directly on the LCD printer and measuring the cured thickness. Penetration depth (Dp) and critical exposure (Ec) were calculated from Jacobs' working-curve analysis. Thin composite films were photopolymerized on the LCD printer at each temperature, and the degree of conversion (DC) (n = 5) was quantified by ATR-FTIR immediately after curing, after post-curing, and after 24 h; real-time polymerization kinetics (n = 5) were evaluated under matched irradiance using a temperature-controlled ATR setup. Flexural strength (FS) and flexural modulus (FM) (n = 30) were determined according to ISO 4049. Data were analyzed using one- and three-way ANOVA followed by Tukey's test (α = 0.05), and flexural strength reliability was assessed by Weibull analysis. MATERIALS AND METHODS METHODS

Viscosity decreased exponentially with temperature, with the greatest drop between 25 and 35 °C. Cure depth increased at elevated temperatures due to improved early polymerization efficiency. DC was significantly affected by temperature, post-curing, and storage time, with no significant interactions, indicating independent effects among the tested variables. The maximum polymerization rate (Rp_max) increased at 50 °C. Flexural strength and Weibull parameters were not altered by temperature, whereas flexural modulus increased slightly but consistently from 25 to 50 °C. RESULTS RESULTS

An increase in 3D-printing temperature reduced viscosity, increased cure depth, enhanced the degree of conversion, accelerated polymerization kinetics, and increased flexural modulus. However, these temperature-dependent changes in rheological and polymerization behavior did not translate into differences in flexural strength or Weibull modulus, and their influence on other aspects of printing performance remains to be established. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42790194/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Heat-assisted vat-polymerization and light irradiance impact on 3D-printed dental resin composites.

Следующая публикация

Effect of scan calibrator morphologies on the accuracy of calibrated complete-arch implant intraoral scans: an in vitro study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее