Effect of restoration span on the accuracy of six intraoral scanners and one dental laboratory scanner evaluated by a virtual-fit method.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Roland Daubner; Vivien Nazar; Laszlo Romanszky; Gyorgy Sersli; Daniel Borbola; Janos Vag

Publication details

Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106915

Publication date (as recorded): 2026-11-30

PMID: 42462805

Abstract (original)

To evaluate the effect of restoration span on scanner-related restoration fit obtained with six intraoral scanners and one dental laboratory scanner. OBJECTIVES OBJECTIVE

A maxillary resin model with eight abutments was scanned with an ATOSQ reference scanner and subsequently with the Aoralscan Elite, Mediti900, Primescan2, R2i3, RunyesV6, and TRIOS6 intraoral scanners, and the AutoScan-DSEXPro(H) laboratory scanner (n = 12 per test scanner). Complete-arch, four-unit bridge, and single-unit restorations were digitally designed. The designed restoration meshes were superimposed on the reference scan using a virtual-fit approach. Marginal gap (MG) and absolute marginal discrepancy (AMD) were calculated for each scanner in the metrology software. Statistical analysis was performed using generalized linear mixed models. METHODS METHODS

Mean MG ranged from 15 to 30 µm for single crowns, 16-44 µm for bridges, and 37-91 µm for complete-arch restorations. MG was significantly higher for bridges than for single crowns for all scanners except AutoScan-DSEXPro(H) and Aoralscan Elite. Complete-arch restorations showed significantly higher MG and AMD than bridges for all scanners, although mean MG remained below the clinically derived, model-based threshold of 100 µm. However, several R2i3 and TRIOS6 scans exceeded this MG threshold. Mean AMD exceeded the threshold for RunyesV6, R2i3, and TRIOS6 in complete-arch restorations. RESULTS RESULTS

Restoration span is a critical determinant of scanning accuracy, particularly when moving from four-unit bridges to complete-arch restorations, even for the laboratory scanner. The virtual-fit method enables robust, clinically interpretable comparison of scanner accuracy across restoration types. CONCLUSIONS CONCLUSIONS

Intraoral scanner selection should consider the intended restoration span. While all evaluated scanners performed well for short-span restorations, only some maintained high accuracy for complete-arch tooth-borne restorations. Because these findings are based on an in vitro study, scanners with lower complete-arch accuracy should be used with caution in clinical practice. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42462805/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Clinical performance of two lithium disilicate CAD/CAM materials in posterior Class II inlay restorations: A 48-month randomised split-mouth clinical trial.

Следующая публикация

Multicenter RCT 6-Year Survival of Zirconia-Reinforced Lithium Silicate Endocrowns: 90° Shoulder Versus Butt-Joint Margins.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее