Effect of scan calibrator morphologies on the accuracy of calibrated complete-arch implant intraoral scans: an in vitro study.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Siyu Wang; Shengtao Yang; Yiping Gu; Li Yue; Junying Li; Quan Yuan

Publication details

Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106983

Publication date (as recorded): 2026-11-30

PMID: 42607924

Abstract (original)

To evaluate the effect of four scan calibrator (SC) morphologies on the accuracy of calibrated complete-arch implant intraoral scans. OBJECTIVE OBJECTIVE

A study model featuring six scan bodies (SBs) at the screw-retained abutment (SRA) level was fabricated, and reference data were obtained by scanning the model with an industrial scanner. A universal SC was manufactured in four morphologies: (1) tubular (SC-TU), (2) crumpled (SC-CR), (3) spherical (SC-SP), and (4) polyhedral (SC-PO). Each SC was attached to the model, and the resulting model-SC assembly was scanned ten times (n = 10) using an intraoral scanner (IOS) to obtain uncalibrated scans. These uncalibrated datasets were then calibrated using the corresponding desktop scans of the SCs. Both the uncalibrated and calibrated scans were registered against the reference scan via two alignment strategies: (1) using all SBs to assess the overall fit, and (2) using only the first and second SBs to simulate the Sheffield test. Linear deviations between the central points of SRAs were calculated using a custom Python script. METHODS METHODS

When aligned using all SBs, trueness was comparable among the four SC-assisted groups, whereas the SC-CR group exhibited significantly lower post-calibration precision (40.11 ± 35.21 μm) than the SC-SP (29.63 ± 17.37 μm) and SC-PO (28.08 ± 13.48 μm) groups. In the virtual Sheffield test, the SC-SP (86.30 ± 34.25 µm) group demonstrated significantly higher trueness than the SC-CR group (162.06 ± 62.45 µm) following calibration at the distal SRA6. Furthermore, the SC-PO (66.21 ± 29.96 μm) group exhibited significantly higher post-calibration precision than the other three SC groups at SRA6. RESULTS RESULTS

SC morphologies influence the accuracy of calibrated complete-arch implant intraoral scans. SC-PO demonstrated the highest post-calibration precision. CONCLUSIONS CONCLUSIONS

The proposed SC morphologies, except for SC-CR, may help correct IOS stitching errors. The polyhedral morphology may represent a favorable design choice for SC fabrication. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42607924/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Effect of printing temperature on the viscosity, photopolymerization, and mechanical properties of a highly filled 3D-printing dental resin composite.

Следующая публикация

Fracture Resistance and Marginal Adaptation of 3D-Printed Versus Milled Resin-Based Permanent Crowns: A Systematic Review and Meta-Analysis.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее