Evaluation of CAD-CAM methods for fabrication of removable partial denture frameworks from commercially pure titanium.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Kosei Ito; Akinori Tasaka; Hiro Kobayashi; Seiichi Nakata; Shuichiro Yamashita

Publication details

Journal of prosthodontic research · 2026 · Vol. 70 · No. 4 · Pages/article no. 652-662

Publication date (as recorded): 2026-11-05

PMID: 41850866

Abstract (original)

Commercially pure titanium (CP-Ti) is ideal for removable partial denture (RPD) frameworks owing to its biocompatibility and corrosion resistance; however, conventional casting can introduce defects and dimensional errors. This study compared the shape accuracy, surface roughness, microstructure, and internal pores of CP-Ti RPD frameworks prepared using four CAD-CAM fabrication methods: (1) Ti-resin: casting from a three-dimensional (3D)-printed resin pattern; (2) Ti-wax: casting from a milled wax pattern; (3) Ti-milling: direct milling from a CP-Ti disc; and (4) Ti-SLM: selective laser melting. PURPOSE OBJECTIVE

Forty frameworks were prepared for each group (N = 10). Shape accuracy was assessed using 3D data-inspection software, surface roughness was analyzed using laser microscopy, the microstructure was determined using X-ray diffraction, and internal pores were examined using micro-computed tomography. Nonparametric statistics (Kruskal-Wallis and Steel-Dwass tests) were used (P < 0.05). METHODS METHODS

Ti-SLM achieved the highest trueness (median: 0.00 mm; IQR: 0.09 mm) and precision (median: 0.01 mm; IQR: 0.02 mm), while Ti-milling yielded the lowest surface roughness (median arithmetic mean height: 0.61 µm; IQR: 0.05 µm). Internal pores were absent in Ti-milling and minimal in Ti-SLM (0-1), whereas Ti-resin and Ti-wax produced 319 and 171 pores (median), respectively. Significant inter-method differences were found in shape accuracy, surface roughness, and pore counts (P < 0.05). RESULTS RESULTS

The fabrication method affected the dimensional accuracy, surface conditions, crystalline features, and internal pores of the CP-Ti frameworks. Ti-milling and Ti-SLM outperformed the casting-based methods (Ti-resin and Ti-wax) in terms of accuracy and defect reduction. These digital approaches may improve the reproducibility and precision of clinical fabrication of CP-Ti RPD frameworks. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/41850866/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Comparative evaluation of translucency changes in pre-shaded and externally stained CAD-CAM ceramics after thermocycling aging.

Следующая публикация

Relationship and spatial differences between mandibular movement and complementary mandibular movement.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее