Long-Term Peri-Implant Crestal Bone Stability Following Digital and Conventional Restorative Workflows: A 5- to 11.6-Year Retrospective Follow-Up.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Michael Klein; Dennis Tarnow

Publication details

Journal of dentistry · 2026 · Pages/article no. 107164

Publication date (as recorded): 2026-11-10

PMID: 43014474

Abstract (original)

To assess long-term peri-implant crestal bone stability around microthreaded, platform-switched implants and explore associations with restorative workflows, abutment characteristics, and prosthetic design. OBJECTIVES OBJECTIVE

This retrospective follow-up included 65 implants in 38 patients from a previously reported cohort. Reported mean clinical observation intervals were 9.1 years after implant placement and 8.5 years after definitive restoration. Mesial and distal bone levels were classified radiographically as improved, maintained, or decreased relative to the restoration baseline. Descriptive analyses considered impression modality, abutment configuration, prosthetic splinting, and surgical variables. For eight implants without new radiographs, the most recent previous classification was retained. No inferential comparisons were conducted. METHODS METHODS

Of 128 evaluable implant surfaces, 28 (21.9%) showed radiographic improvement, 84 (65.6%) remained stable, and 16 (12.5%) showed a decrease; the combined improvement or maintenance rate was 87.5%. Favorable outcomes were recorded for 86.9% of surfaces in the digital-impression group and 88.6% in the conventional-impression group. Bone maintenance was observed on 74.1% of splinted surfaces and 59.5% of single-unit surfaces. Multi-unit abutments showed 82.6% maintenance. Overall, 64 of 65 implants (98.5%) met the applied radiographic bone-level criterion. RESULTS RESULTS

Most evaluable implant surfaces maintained or improved their radiographic crestal bone levels over the documented follow-up. Digital and conventional impression groups showed similar descriptive outcomes; associations with abutment selection and splinting remained exploratory. CONCLUSIONS CONCLUSIONS

These long-term observations are reassuring for implant restorations fabricated using digital impressions. The findings do not establish biological equivalence or isolate the effects of individual restorative components; prospective studies with standardized follow-up are needed. CLINICAL RELEVANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/43014474/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Accuracy and Efficiency of Artificial Intelligence-assisted Dental Restoration Design: A systematic Review and Meta-analysis.

Следующая публикация

Comparison of three occlusal splint material systems manufactured by conventional, subtractive, and additive techniques.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее