Abstract (original)
To compare microscope-assisted and loupe-assisted refinement of predoctoral crown preparations on the marginal adaptation of CAD-CAM zirconia crowns, using unrefined preparations as controls. OBJECTIVES OBJECTIVE
Third-year dental students prepared 160 typodont maxillary central incisors under ×3.0-×3.5 loupes. Five deficient preparations were excluded. Sixty of the remaining 155 were randomly selected and allocated to three groups (n = 20): LOUP-C (no refinement), LOUP-RF (2-minute loupe-assisted refinement), and DOM-RF (2-minute microscope-assisted refinement, up to ×10). A single calibrated third-year student performed all refinements. Following standardized CAD-CAM zirconia crown fabrication and cementation, marginal gap distances were measured at 24 locations per specimen using three-dimensional digital analysis. Data were analyzed using a linear mixed model with Tukey-Kramer adjustment (α = .05). METHOD AND MATERIALS METHODS
Mean (± SD) marginal gaps were 110.50 ± 39.88 μm (LOUP-C), 112.01 ± 32.26 μm (LOUP-RF), and 82.12 ± 14.87 μm (DOM-RF). DOM-RF demonstrated smaller marginal gaps than LOUP-C (difference, 28.38 μm; 95% CI, 16.96-39.81 μm; P < .0001) and LOUP-RF (difference, 29.89 μm; 95% CI, 21.28-38.51 μm; P < .0001). LOUP-C and LOUP-RF did not differ significantly (P = .96). RESULTS RESULTS
Under standardized in vitro conditions, microscope-assisted preparation refinement improved the marginal adaptation of CAD-CAM zirconia crowns fabricated from predoctoral preparations compared with loupe-assisted refinement or no refinement. CONCLUSIONS CONCLUSIONS