Effectiveness of digitally fabricated versus conventional stabilizing splints in temporomandibular disorders: a randomized controlled trial protocol.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Aysha Sadaf; Nazia Yazdanie; Muhammad Khan Asif

Publication details

BDJ open · 2026 · Vol. 12 · No. 1

Publication date (as recorded): 2026-11-15

PMID: 43039906

Abstract (original)

Temporomandibular disorders (TMD) comprise a group of conditions affecting the muscles and temporomandibular joints of the stomatognathic system and may result in pain, joint dysfunction, and impaired mandibular function. Stabilization splints are commonly used as a conservative treatment modality for TMD. Conventional splint fabrication using heat-cured acrylic resin is technique-sensitive and may be associated with variability in fabrication and clinical adjustment. Digital workflows incorporating computer-aided design and computer-aided manufacturing (CAD/CAM), followed by additive manufacturing, may improve standardization, reproducibility, and fabrication accuracy. However, clinical evidence directly comparing digitally fabricated and conventionally fabricated stabilization splints remains limited. BACKGROUND BACKGROUND

This single-center, two-arm, parallel-group randomized controlled trial will compare digitally fabricated and conventionally fabricated maxillary stabilization splints. A total of 120 participants aged 18-40 years with temporomandibular joint (TMJ) arthralgia diagnosed according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) axis I will be recruited and randomly allocated in a 1:1 ratio to the digital or conventional stabilization splint group. All splints will have standardized design, coverage, thickness, and occlusal characteristics. Outcome assessment will be performed by a blinded assessor. The primary outcome is the change in Characteristic Pain Intensity (CPI; 0-100) from baseline to 3 months. Secondary outcomes include pain-related disability, maximum unassisted mouth opening, jaw functional limitation, temporomandibular joint clicking, oral health-related quality of life, and splint compliance. Participants will be analyzed according to their original randomized allocation, irrespective of treatment adherence or discontinuation. The primary outcome will be analyzed using linear mixed-effects modeling, including treatment group, time, and treatment-by-time interaction. PARTICIPANTS AND METHODOLOGY UNASSIGNED

This trial aims to provide clinical evidence regarding the comparative effectiveness of digitally fabricated and conventionally fabricated stabilization splints for the management of TMD. The findings may inform evidence-based selection of splint fabrication workflows and help determine whether the potential advantages of digital fabrication translate into comparable or improved clinical outcomes. DISCUSSION CONCLUSIONS

Prospectively registered at ClinicalTrials.gov: NCT07566936. TRIAL REGISTRATION BACKGROUND

Source: https://pubmed.ncbi.nlm.nih.gov/43039906/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Influence of Implant Angulation on the Accuracy of Complete-Arch Digital Scans with Intraoral Photogrammetry.

Следующая публикация

Effect of Thermocycling and Bleaching on the Color Stability and Lightness of Monolithic CAD/CAM Dental Ceramics.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее