Comparison of Conventional and Digital Intraoral Scanning Method for Obtaining Complete-Arch Dental Impressions.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Kunal Bhutada; Krishna Prasad D; Chethan Hegde; Athma Shetty

Publication details

The International journal of prosthodontics · 2026 · Vol. 39 · No. 6 · Pages/article no. 811-817

Publication date (as recorded): 2026-11-17

PMID: 40748750

Abstract (original)

To compare the accuracy of digital and conventional complete-arch impressions in a clinical setting. PURPOSE OBJECTIVE

An in vitro study was first conducted using a full-arch maxillary Nissin typodont reference model. Three intraoral scanners-CEREC Primescan (Dentsply Sirona), Virtuo Vivo (Straumann), and TRIOS 3 (3Shape)-were compared against conventional vinyl polysiloxane (VPS) impressions. STL files were analyzed using Exocad DentalCAD software, employing best-fit alignment and cut-view analysis at three key regions: the cusp of the maxillary right canine, the palatal cusp of the maxillary left second premolar, and the mesiobuccal cusp of the maxillary right first molar. A secondary clinical evaluation involved eight participants, each contributing three digital scans and one conventional VPS impression, resulting in a total of 32 samples (4 per participant). All STL files were analyzed using the same protocol. Statistical tests included one-way ANOVA and post-hoc Tukey test (P < .05). MATERIALS AND METHODS METHODS

In clinical analysis, Virtuo Vivo showed the lowest discrepancy at the maxillary right canine (0.042 ± 0.015 mm), and TRIOS 3 showed the highest discrepancy (0.061 ± 0.020 mm; P = 0.394). At the left second premolar, TRIOS 3 had the lowest discrepancy (0.039 ± 0.014 mm), and Primescan had the highest discrepancy (0.059 ± 0.021 mm; P = 0.790). For the right first molar, Primescan showed the lowest discrepancy (0.047 ± 0.016 mm), and Virtuo Vivo showed the highest discrepancy (0.063 ± 0.022 mm; P = 0.330). Differences were not statistically significant; digital impressions were comparable in accuracy to conventional methods. RESULTS RESULTS

Digital impressions are a reliable alternative to conventional impressions, with minimal differences in accuracy. Regional variation highlights the importance of technique and scanner-specific optimization. Ongoing advancements in intraoral scanning technology continue to improve clinical precision. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/40748750/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Conventional Gingival Characterisation for Implant-Supported Fixed Complete Denture Using a Hybrid Workflow: A Clinical Report.

Следующая публикация

Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее