Guided bone regeneration with polytetrafluoroethylene titanium-reinforced membrane, CAD/CAM semi-occlusive titanium mesh and CAD/CAM occlusive titanium foil in partially atrophic arches: A comparative randomised controlled trial with 3-year follow-up.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Pietro Felice; Gerardo Pellegrino; Roberto Pistilli; Subhi Tayeb; Martina Casaburi; Massimo Simion; Carlo Barausse

Publication details

International journal of oral implantology (Berlin, Germany) · 2026 · Vol. 19 · No. 4 · Pages/article no. 351-362

Publication date (as recorded): 2026-11-18

PMID: 43055193

Abstract (original)

To evaluate the effectiveness of three distinct guided bone regeneration devices, namely non-resorbable polytetrafluoroethylene membrane, semi-occlusive CAD/CAM titanium mesh and occlusive CAD/CAM titanium foil, over a 3-year period, focusing on clinical and radiographic outcomes. PURPOSE OBJECTIVE

Twenty-seven partially edentulous patients with alveolar atrophy requiring guided bone regeneration for implant placement were enrolled and randomly allocated to one of three treatment groups (polytetrafluoroethylene, mesh or foil). Surgical time and surgical satisfaction were assessed and compared among the groups. The present study reports the 3-year clinical outcomes update, including marginal bone loss and complications. MATERIALS AND METHODS METHODS

Mean marginal bone loss at 3 years was 0.82 ± 0.46 mm in the polytetrafluoroethylene group, 0.95 ± 0.36 mm in the mesh group and 0.92 ± 0.61 mm in the foil group, with no significant association between device type. Six bone augmentation-related complications occurred, with no significant difference among groups (P = 0.842). Five implant-related complications were recorded among 60 implants (P = 0.730), including one implant failure; no prosthetic failures occurred. Smoking was significantly associated with greater marginal bone loss at 3 years (P = 0.015). CAD/CAM mesh and foil were associated with shorter surgical times and greater surgeon satisfaction than polytetrafluoroethylene membrane. RESULTS RESULTS

All three guided bone regeneration devices were associated with favourable and comparable clinical and radiographic outcomes at 3 years. Customised CAD/CAM titanium mesh and foil maintained good peri-implant bone stability similar to titanium-reinforced polytetrafluoroethylene membrane, while offering advantages in intraoperative handling and surgical time. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/43055193/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Long-Term Retention Force and Fatigue Performance of CAM PEEK Clasps: An In Vitro Study.

Следующая публикация

Conventional Gingival Characterisation for Implant-Supported Fixed Complete Denture Using a Hybrid Workflow: A Clinical Report.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее