Original PubMed abstract — English. No translation or clinical interpretation.
Authors
Youcheng Luo; Xiaocui Wei; Shuang Yang; Qian Liang; Zhe Wu; Xinchao Miao
Publication details
Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106827
Publication date (as recorded): 2026-11-30
PMID: 42285211
Abstract (original)
To compare the accuracy of different acquisition strategies for CAD-CAM post-and-core restorations in molars with dual post spaces and to explore the underlying technique-specific error mechanisms. OBJECTIVES OBJECTIVE
Three representative molar cases were selected in which CAD-CAM glass fiber post-and-core restorations fabricated from conventional quadrant impressions showed poor seating, marginal discrepancy, or optimal adaptation. Three-dimensional printed models derived from these cases were used for controlled in vitro evaluation. Four polyvinyl siloxane (PVS) impression techniques were tested using quadrant or single-tooth trays, with or without impression posts, and two direct digital scanning approaches were evaluated using Primescan and Trios 3 scanners. Accuracy was assessed qualitatively and quantitatively using depth difference (Δdepth), apical deviation, and root mean square (RMS) values. METHODS METHODS
PVS impressions without impression posts and direct Primescan scanning demonstrated the highest trueness and repeatability. In pooled analysis, these methods showed median Δdepth values of 0.02-0.04 mm and median RMS values of 59-65 μm, with apical deviation values remaining low at 0.00-0.06 mm. In contrast, PVS impressions incorporating impression posts were associated with greater distortion, with median Δdepth values of 0.25-0.37 mm, median apical deviation values of 0.20-0.32 mm, and median RMS values of 113-137 μm. Direct Trios 3 scanning showed a different error pattern, characterized by incomplete apical capture and increased overall deviation, with median Δdepth value of 0.31 mm and median RMS value of 83 μm despite relatively small median apical deviation value. RESULTS RESULTS
In dual-post molars, PVS impressions without impression posts and direct Primescan scanning provide the most reliable acquisition accuracy. Routine use of impression posts may introduce removal-induced distortion and should be applied selectively. Conventional impressions and direct digital workflows are affected by distinct mechanical and optical limitations, respectively. CONCLUSIONS CONCLUSIONS
For CAD-CAM post-and-core restorations in dual-post molars, PVS impressions without impression posts and direct Primescan scanning may represent suitable strategies for improving acquisition accuracy and restoration adaptation, which may support long-term tooth preservation. CLINICAL SIGNIFICANCE CONCLUSIONS
Source: https://pubmed.ncbi.nlm.nih.gov/42285211/