Effects of auxiliary devices for intraoral scanning on the accuracy of scan bodies and implant positioning accuracy for prosthetic design.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Gyu-Ri Kim; KeunBaDa Son; So-Yeun Kim; Kyu-Bok Lee

Publication details

Journal of prosthodontic research · 2026 · Vol. 70 · No. 4 · Pages/article no. 591-603

Publication date (as recorded): 2026-11-05

PMID: 41605680

Abstract (original)

This study evaluated the effects of auxiliary devices on the scanning accuracy of scan bodies and implant positioning accuracy for dental prosthetic design. PURPOSE OBJECTIVE

Four implants were placed in an edentulous maxillary model and fitted with scan bodies. Two types of removable auxiliary devices were designed and 3D-printed for intraoral scanning, categorized into three groups: non-auxiliary device (NAD), geometric-shaped device (GAD), and tooth-shaped device (TAD) groups. Scanning was performed using three intraoral scanners (i700, i500, and Primescan), with ten scans acquired per group. The scanning accuracy of scan bodies was assessed using 3D inspection software (Zeiss Inspect; Zeiss), whereas implant positioning accuracy after scan body library alignment was analyzed using Geomagic Control X (3D Systems) and Zeiss Inspect. Statistical analyses were performed using one-way and two-way ANOVA followed by Tukey HSD tests to compare the performance among the three groups (α = 0.05). METHODS METHODS

The TAD group demonstrated significantly lower linear discrepancy in the anterior and posterior scan body distance for the i700 and i500 (P < 0.001). However, in terms of implant position accuracy after scan body library alignment, the NAD group with the i700 system showed significantly lower root mean square (RMS) values (P = 0.001) and also demonstrated significantly lower deviation in the apical region (P = 0.005). RESULTS RESULTS

The use of auxiliary devices for intraoral scanning improved the accuracy of the scan body; however, these devices had little or even a detrimental effect on implant positioning accuracy after scan body library alignment in the CAD process. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/41605680/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Adherence assessment of Candida albicans on CAD/CAM and conventional resin for denture base: A systematic review and network meta-analysis.

Следующая публикация

3D digital data analysis to identify factors influencing debonding of CAD-CAM resin composite molar crowns: A 4-year clinical study.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее