Wear performance of microlayered zirconia crowns and method-dependent comparison of integrated and external scanning workflows.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Svenja Stuhr; Mustafa Borga Dönmez; John Meinen; Daniel Edelhoff; Alexis Ioannidis; Bogna Stawarczyk

Publication details

Clinical oral investigations · 2026 · Vol. 30 · No. 12

Publication date (as recorded): 2026-11-06

PMID: 42995302

Abstract (original)

This in vitro study evaluated the wear performance of microlayered (ML) zirconia crowns and investigated method-dependent differences in volumetric loss estimates obtained using scanner-integrated and external laser-scanning workflows. OBJECTIVES OBJECTIVE

A mandibular first molar crown design was used to fabricate ML (CER, IQS, MIY, and STR; n = 8 per ceramic) and monolithic zirconia (MZ) crowns (n = 3). All crowns were subjected to 600000 cycles in a scanner-integrated mastication simulator (50 N, 2.5 Hz), with surface data recorded at baseline and after 60000, 120000, and 600000 cycles. External laser scans were additionally obtained at baseline and after 600000 cycles. Separate linear mixed-effects models were used to assess longitudinal volumetric loss across evaluation time points for the 4 microlayering ceramics and to compare post-aging volumetric loss estimates between scanning workflows at 600000 cycles. MZ was evaluated descriptively as a negative control (α = 0.05). MATERIALS AND METHODS METHODS

STR showed lower volumetric loss than MIY and IQS (p ≤ 0.018). Volumetric loss increased significantly with mastication cycles (p < 0.001). No measurable volumetric loss was observed for MZ. Volumetric loss estimates were affected by the scanning workflow and its interaction with the microlayering ceramic (p ≤ 0.001). External laser-scanning yielded significantly higher volumetric loss estimates (p ≤ 0.048). RESULTS RESULTS

STR exhibited significantly lower estimated marginal mean volumetric loss than MIY and IQS, while the volumetric loss increased progressively. No measurable volumetric loss was observed for MZ. Volumetric loss estimates were higher with the external laser-scanning workflow, with material-dependent differences. CONCLUSIONS CONCLUSIONS

Tested microlayering ceramics influenced the wear behavior of ML crowns. The scanner-integrated workflow enabled longitudinal monitoring of relative wear; however, workflow-dependent volumetric loss estimates precluded conclusions on absolute wear, agreement, interchangeability, or measurement superiority. CLINICAL RELEVANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42995302/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026

Поделиться этой информацией
URL публикации
Предыдущая публикация

Effects of build orientation on the mechanical and surface properties of polyetheretherketone fabricated with fused deposition modeling.

Следующая публикация

Telescopic prosthesis for extensive mandibular tooth loss with a polyetherketoneketone framework fabricated using digital workflow: A case report.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее