Accuracy and Efficiency of Artificial Intelligence-assisted Dental Restoration Design: A systematic Review and Meta-analysis.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Nadin Al-Haj Husain; Hüseyin Seker; Hyuing-In Yoon; Richard Johannes Wierichs; Burak Yilmaz

Publication details

Journal of dentistry · 2026 · Pages/article no. 107168

Publication date (as recorded): 2026-11-14

PMID: 43035139

Abstract (original)

To compare the accuracy and time efficiency of artificial intelligence (AI)-assisted software with conventional dental computer-aided design (CAD) software for designing dental restorations. OBJECTIVES OBJECTIVE

Following PRISMA 2020, five electronic databases (PubMed, Web of Science, Embase, Scopus, and the Cochrane Library) were searched to August 4, 2026. In vitro and clinical studies comparing AI-assisted and conventional CAD software for digital dental restoration design were eligible. Outcomes included design time, morphology, restoration fit, and proximal and occlusal contacts. Risk of bias was assessed using the QUIN tool. Random-effects meta-analyses (REML, Hartung-Knapp adjustment) were performed, with 95% prediction intervals (PI), τ and I² with 95% CIs. DATA AND SOURCES METHODS

Twenty-eight studies met the eligibility criteria; 10 were pooled. Design time (4 studies) showed a non-significant mean difference of -258.4 s (95% CI -543.2 to 26.4; 95% PI -1100.2 to 583.5). Pooled SMDs were -2.05 for root mean square deviation (8 studies; 95% CI -4.88 to 0.78; 95% PI -10.25 to 6.15). Heterogeneity was substantial (I² = 80-97%, τ=0.82-3.13). Restoration fit (marginal gap, marginal fit, internal fit; three studies or fewer each) and occlusal outcomes were synthesized narratively. AI-assisted software generally produced clinically acceptable restorations, although technician refinement remained beneficial. AI-assisted software generally produced clinically acceptable restorations, although technician refinement remained beneficial for contour, emergence profile, and occlusal contacts. STUDY SELECTION/RESULTS RESULTS

Evidence, almost entirely in vitro studies and highly heterogeneous, is inconclusive regarding differences in design time, morphological accuracy and restoration fit. Design time tended to be shorter with AI-assisted software. CONCLUSIONS CONCLUSIONS

AI-assisted design software may shorten design time, but current evidence does not allow firm conclusions about restoration quality relative to conventional CAD. Well-designed, preferably clinical, comparative studies with standardized outcomes are needed for further evaluation. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/43035139/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Comparative evaluation of the wear of natural teeth opposing CAD-CAM milled zirconia and BioHPP: An in vitro study.

Следующая публикация

Long-Term Peri-Implant Crestal Bone Stability Following Digital and Conventional Restorative Workflows: A 5- to 11.6-Year Retrospective Follow-Up.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее