Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Ra'fat I Farah; Abdulmajeed Alwably; Abdulaziz Alfurayhi; Asim Alfawzan

Publication details

The International journal of oral & maxillofacial implants · 2026 · Vol. 0 · No. 0 · Pages/article no. 1-27

Publication date (as recorded): 2026-11-19

PMID: 43063502

Abstract (original)

To evaluate the accuracy of implant spatial positions obtained through a proposed bite holder digital substitution workflow compared to conventional direct scan body scanning. PURPOSE OBJECTIVE

A mandibular model with four implant analogs was fabricated and digitized with a desktop scanner to establish the reference standard. Two protocols were compared: direct scan body scanning (n=10) and bite holder scanning with digital substitution (n=10), both performed with an intraoral scanner. In the substitution method, bite holders were virtually replaced with scan bodies using a superimposition workflow in computer-aided design (CAD) software. Three-dimensional RMS deviation, linear deviation, and angular deviation were quantified using metrology software. Hotelling's T² test compared overall accuracy between methods (α=0.05), followed by protected univariate tests with Bonferroni correction. An equivalence analysis was performed using the two one-sided tests procedure with clinical margins of ±100 μm and ±0.4°. MATERIAL AND METHODS METHODS

Direct scanning achieved RMS, linear, and angular deviations of 56.3±14.5 μm, 67.5±15.7 μm, and 0.37±0.06°, respectively. The substitution method demonstrated 85.2±18.0 μm, 96.6±15.0 μm, and 0.63±0.07°, respectively. Direct scanning showed statistically superior accuracy (P<.001); however, the 90% confidence intervals of all mean differences fell entirely within the predefined equivalence margins, indicating that the differences were smaller than the clinically relevant limits. RESULTS RESULTS

Digital substitution of bite holders with scan bodies achieved clinically acceptable accuracy for implant position registration under in vitro conditions, with differences from direct scan body scanning within the predefined equivalence margins This design enables simultaneous single-visit capture of implant positions and maxillomandibular relationships (MMR), warranting clinical validation. CONCLUSIONS CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/43063502/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Comparison of Conventional and Digital Intraoral Scanning Method for Obtaining Complete-Arch Dental Impressions.

Следующая публикация

Effect of the Sintering Speed of Large Laboratory Furnaces on Marginal and Internal Gaps of CAD/CAM Monolithic Zirconia Crowns.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее