Effects of printing orientation and postpolymerization time on the color stability, gloss, surface roughness, and Vickers hardness of an additively manufactured occlusal splint material.

Original PubMed abstract — English. No translation or clinical interpretation.

Authors

Dalndushe Abdulai; Rafat Sasany; Omir Aldowah; Seyed Ali Mosaddad

Publication details

Journal of dentistry · 2026 · Vol. 175 · Pages/article no. 106884

Publication date (as recorded): 2026-11-30

PMID: 42413710

Abstract (original)

This in vitro study evaluated the effects of printing orientation and postpolymerization time on the color stability, gloss, surface roughness, and Vickers hardness of an occlusal splint material fabricated by additive manufacturing after artificial aging. OBJECTIVE OBJECTIVE

Disc-shaped specimens were fabricated from a photopolymer occlusal splint resin at 0-degree, 45-degree, and 90-degree printing orientations and subjected to 10- or 20 min postpolymerization. Separate specimen sets were used for optical, surface-roughness, and Vickers-hardness evaluations. Color stability and gloss specimens were thermocycled and then immersed in distilled water, coffee, or black tea. Surface roughness and Vickers hardness were measured before and after thermocycling. Color differences were calculated by using the CIEDE2000 formula. Data were analyzed by using Generalized Estimating Equations, effect-size estimates, and Bonferroni-adjusted multiple comparisons (α = .05). METHODS METHODS

Printing orientation affected color stability after coffee (p = .016; ηp² = 0.064) and black tea immersion (p = .009; ηp² = 0.072), gloss (p < .001; ηp² = 0.120), and Vickers hardness (p < .001; ηp² = 0.115), but not surface roughness. Postpolymerization time affected coffee-related color change (p = .030; ηp² = 0.038) and gloss (p = .017; ηp² = 0.040). Aging condition showed the largest effects across outcomes, particularly for color stability, gloss, and Vickers hardness (ηp² = 0.439 to 0.903). Staining media increased color change and reduced gloss, whereas thermocycling increased surface roughness and substantially reduced Vickers hardness. RESULTS RESULTS

Within the limitations of this in vitro study and for the tested material-printer-postpolymerization workflow, printing orientation, postpolymerization time, and aging condition influenced the evaluated properties, although the magnitude and direction of these effects varied by outcome. CONCLUSIONS CONCLUSIONS

Manufacturing parameters and aging conditions may affect the optical, surface, and mechanical behavior of occlusal splints fabricated by additive manufacturing. The selection of printing orientation and postpolymerization time should consider esthetic stability, surface quality, and mechanical performance. CLINICAL SIGNIFICANCE CONCLUSIONS

Source: https://pubmed.ncbi.nlm.nih.gov/42413710/


Обложка Альманаха Том 2

Альманах книг по НЕсъёмному протезированию: Анализ литературы

Эволюция несъемного ортопедического лечения за последние полтора века (1860–2026 гг.) — это не просто последовательность изобретения новых боров, слепочных масс или зуботехнических печей. Это история постепенного укрощения деструктивных сил жевательного давления и подчинения искусственных материалов биологии живых тканей.

Том. 6 • 2026
Обложка Альманаха Том 2

Альманах книг по съёмному протезированию: Анализ литературы

Собранные воедино труды ведущих мировых школ позволяют досконально разобрать алгоритмы распределения жевательного давления, физику замыкающего клапана и микромеханику замковых креплений, исключая ремесленнический подход в пользу осознанной доказательной практики и биомиметического восстановления функции.

Том. 7 • 2026
Поделиться этой информацией
URL публикации
Предыдущая публикация

Enhancing printing accuracy and mechanical properties of DLP dental resin via silanized cellulose nanocrystals.

Следующая публикация

Fatigue behaviour of direct and CAD/CAM indirect restorative materials bonded to a dentine analogue substrate.

Добавить комментарий

Ваш адрес email не будет опубликован. Обязательные поля помечены *

Смотреть далее